https://www.mdu.se/

mdh.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Non-invasive techniques for assessment of peripheral blood flow at different vascular depths
Mälardalens högskola, Akademin för innovation, design och teknik. (ISS)
2011 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Missing or reduced blood flow can lead to pressure ulcers. Monitoring blood flow in areas prone to pressure ulcer development would be a valuable tool for prevention of pressure ulcers.

PPG and LDF are both established non invasive optical techniques that can be used to estimate the changes in blood flow in different tissue volumes. The aim of this thesis was to combine the established techniques, LDF and PPG, into one flexible silicon probe intended for evaluation of peripheral blood flow in tissue volumes prone to pressure ulcer development. Further, a temperature sensor was integrated.

Two probe configurations combining LDF and PPG has been evaluated regarding the ability to separate between shallow, medium and deep blood flow variations, and skin temperature changes. Further, techniques to reduce or totally avoid interference between LDF and PPG have been investigated.

The probes can be used to discriminate between blood flows at different vascular depths. The vascular depths reached by the different channels correspond to the depths of interest when investigating pressure ulcer aetiology. The probe itself has shown not to affect the skin surface temperature, neither due to the silicon sheet or the light. The skin temperature can be expected to rise and approach the body core temperature by lying in supine position alone, which has to be taken into consideration when designing studies.

By switching between the different light sources, interference can be totally avoided. When rapid blood flow variations at several vascular depths are of interest to evaluate, a peripheral placement of the LDF-fibre and an increased illumination power of the PPG-LEDs might be used to minimize the interference between LDF and PPG.

Both probes have shown potential to be used for investigation of the processes in pressure ulcer development.

sted, utgiver, år, opplag, sider
Västerås: Mälardalen University , 2011.
Serie
Mälardalen University Press Licentiate Theses, ISSN 1651-9256 ; 131
Forskningsprogram
elektronik
Identifikatorer
URN: urn:nbn:se:mdh:diva-12226ISBN: 978-91-7485-014-7 (tryckt)OAI: oai:DiVA.org:mdh-12226DiVA, id: diva2:415696
Presentation
2011-05-19, Pi, Högskoleplan 1, Västerås, 14:00 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2011-05-09 Laget: 2011-05-09 Sist oppdatert: 2025-10-10bibliografisk kontrollert
Delarbeid
1. Assessment of the optical interference in a PPG-LDF system used for estimation of tissue blood flow
Åpne denne publikasjonen i ny fane eller vindu >>Assessment of the optical interference in a PPG-LDF system used for estimation of tissue blood flow
2011 (engelsk)Inngår i: IFMBE PROCEEDINGS: 15th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2011; Aalborg; 14 June 2011 through 17 June 2011 / [ed] Kim Dremstrup, 2011Konferansepaper, Publicerat paper (Fagfellevurdert)
HSV kategori
Forskningsprogram
elektronik
Identifikatorer
urn:nbn:se:mdh:diva-12223 (URN)10.1007/978-3-642-21683-1_4 (DOI)000308452500004 ()2-s2.0-79959985250 (Scopus ID)9783642216824 (ISBN)
Tilgjengelig fra: 2011-05-09 Laget: 2011-05-09 Sist oppdatert: 2025-10-10bibliografisk kontrollert
2. Long-term monitoring of blood flow at different depths using LDF and PPG - issues to consider
Åpne denne publikasjonen i ny fane eller vindu >>Long-term monitoring of blood flow at different depths using LDF and PPG - issues to consider
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
HSV kategori
Forskningsprogram
elektronik
Identifikatorer
urn:nbn:se:mdh:diva-12224 (URN)
Tilgjengelig fra: 2011-05-09 Laget: 2011-05-09 Sist oppdatert: 2025-10-10bibliografisk kontrollert
3. A technique based on laser Doppler flowmetry and photoplethysmography for simultaneously monitoring blood flow at different tissue depths
Åpne denne publikasjonen i ny fane eller vindu >>A technique based on laser Doppler flowmetry and photoplethysmography for simultaneously monitoring blood flow at different tissue depths
Vise andre…
2010 (engelsk)Inngår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 48, nr 5, s. 415-422Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The aim of this study was to validate a non-invasive optical probe for simultaneous blood flow measurement at different vascular depths combining three photoplethysmography (PPG) channels and laser Doppler flowmeter (LDF). Wavelengths of the PPG were near-infrared 810 nm with source-to-detector separation of 10 and 25 mm, and green 560 nm with source-to-detector separation of 4 mm. The probe is intended for clinical studies of pressure ulcer aetiology. The probe was placed over the trapezius muscle, and depths from the skin to the trapezius muscle were measured using ultrasound and varied between 3.8 and 23 mm in the 11 subjects included. A provocation procedure inducing a local enhancement of blood flow in the trapezius muscle was used. Blood flows at rest and post-exercise were compared. It can be concluded that this probe is useful as a tool for discriminating between blood flows at different vascular tissue depths. The vascular depths reached for the different channels in this study were at least 23 mm for the near-infrared PPG channel (source-to-detector separation 25 mm), 10-15 mm for the near-infrared PPG channel (separation 10 mm), and shallower than 4 mm for both the green PPG channel (separation 4 mm) and LDF.

Identifikatorer
urn:nbn:se:mdh:diva-11049 (URN)10.1007/s11517-010-0577-2 (DOI)000276771800002 ()20107915 (PubMedID)2-s2.0-77955583312 (Scopus ID)
Tilgjengelig fra: 2010-11-11 Laget: 2010-11-11 Sist oppdatert: 2025-10-10bibliografisk kontrollert

Open Access i DiVA

fulltekst(869 kB)2033 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 869 kBChecksum SHA-512
3755d6286bb13694ceb3f7cec77b401f48ae0b7a0307f659c49ce7e828f95a76177d19a6d3f0a5b1d4a2c5b2e5ec2e44a4841aa509f67b86315f911aea9555e2
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Hagblad, Jimmie
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 2033 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 671 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf