https://www.mdu.se/

mdu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Improving central apnea detection in preterm infants: Neural network strategies and clinical impact
Mälardalen University, School of Innovation, Design and Engineering, Embedded Systems. Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands; Gynecology, Máxima Medical Center, Veldhoven, Netherlands. (Neuroengineering)ORCID iD: 0000-0002-9107-0420
Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
Show others and affiliations
2025 (English)In: Computer Methods and Programs in Biomedicine, ISSN 0169-2607, E-ISSN 1872-7565, Vol. 272, article id 109038Article in journal (Refereed) Published
Abstract [en]

Background and objective: Preterm infants are characterized by immature cardiorespiratory systems and require continuous monitoring of physiological signals in neonatal intensive care units (NICUs) to assess their clinical condition and return alarms in critical situations. However, many alarms are false or clinically irrelevant, leading to alarm fatigue for nurses and clinicians. A particularly high false alarm rate is reported for central apneas (CAs), with precision as low as 0.35. This study proposes neural networks to improve CA detection by increasing precision. Methods: We used a reference dataset of 10 preterm infants (951 annotated CAs across 480 h) and a hold-out dataset of 10 preterm infants characterized by fewer CAs (254 annotated CAs across 480 h). CA detection models were developed using features extracted from the electrocardiogram, chest impedance, and peripheral oxygen saturation, considering four consecutive 30-second moving windows with a 5-second time shift (four-window sets) as individual records. These were trained, optimized, and tested using different neural network architectures, hyperparameter tuning, and leave-one-patient-out cross-validation. Their evaluation was performed through different metrics, including precision, computed by considering all CAs and apneic events of different origins, and sensitivity for all CAs, CAs paired with bradycardia (heart rate, HR ≤ 80 bpm), and CAs paired with low HR (80 bpm < HR ≤ 100 bpm). Results: The best-performing CA detection model, using convolutional neural networks (CNN), was trained and tested on the reference dataset. By retaining alarms detected in 5 four-window sets, it achieved a precision of 0.54 and a sensitivity of 0.75 for all CAs, 0.87 for CAs paired with bradycardia, and 0.88 for CAs paired with low HR, outperforming results found in previous studies and current clinical practice. Testing on the hold-out dataset showed a decrease in precision and sensitivity for all CAs, equal to 0.28 and 0.69, respectively. However, the sensitivity for CAs paired with bradycardia and with low HR remained high at 0.83 and 0.85. Conclusions: Larger datasets with more diverse CA distributions are needed to enhance generalization. Neural networks demonstrated potential to improve CA detection and reduce false alarms in NICUs, supporting more accurate monitoring strategies for preterm infants. 

Place, publisher, year, edition, pages
Elsevier BV , 2025. Vol. 272, article id 109038
Keywords [en]
Central Apneas, Machine Learning, Neural Networks, Preterm Infants, Alarm Systems, Biomedical Signal Processing, Convolutional Neural Networks, Electrocardiography, Errors, Image Resolution, Neonatal Monitoring, Statistical Tests, Apnea Detection, Detection Models, Machine-learning, Moving Window, Neonatal Intensive Care Units, Network Strategy, Neural-networks, Time Shifts, Learning Systems
National Category
Pediatrics
Identifiers
URN: urn:nbn:se:mdh:diva-73314DOI: 10.1016/j.cmpb.2025.109038ISI: 001569292700002PubMedID: 40915096Scopus ID: 2-s2.0-105015048600OAI: oai:DiVA.org:mdh-73314DiVA, id: diva2:1998590
Available from: 2025-09-17 Created: 2025-09-17 Last updated: 2026-04-29Bibliographically approved

Open Access in DiVA

fulltext(1062 kB)6 downloads
File information
File name FULLTEXT01.pdfFile size 1062 kBChecksum SHA-512
a9462a63240887e4704e8f026158dd5367781a6eb6bf4518528389f58f488ed0f3354b01e12f8febdddec6d372b2c57e14bf182bd4a6c378aed318095aa1f3e4
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Varisco, Gabriele

Search in DiVA

By author/editor
Varisco, Gabriele
By organisation
Embedded Systems
In the same journal
Computer Methods and Programs in Biomedicine
Pediatrics

Search outside of DiVA

GoogleGoogle Scholar
Total: 6 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 14 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf